From 6ea1a42391f86e72f53042a966dae970a3fd77cb Mon Sep 17 00:00:00 2001 From: jinlicong <493886250@qq.com> Date: Fri, 17 May 2024 17:18:57 +0800 Subject: [PATCH] 阀门控制进一步完善 --- KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm | 25 ++----------------------- 1 files changed, 2 insertions(+), 23 deletions(-) diff --git a/KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm b/KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm index e597efb..3a90640 100644 --- a/KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm +++ b/KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm @@ -22,34 +22,13 @@ <h2>Project:</h2> E:\GasFlowmeter\Internet_of_things_valve\SZV103\SZV103_FM33A0xxEV_SiZhu\KEIL_MDKARM\SZV103_FM33A0_MainSystem.uvprojx -Project File Date: 04/24/2024 +Project File Date: 05/16/2024 <h2>Output:</h2> *** Using Compiler 'V5.06 update 7 for Certification (build 960)', folder: 'D:\Program Files\MDK5\ARM\ARMCC\Bin' Build target 'SZV103_FM33A0_MainSystem' -compiling rs485_data_analysis_pro.c... -..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(68): warning: #177-D: variable "SC_Accumulation_zs" was declared but never referenced - uint32_t SC_Accumulation_zs; -..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(69): warning: #177-D: variable "SC_Accumulation_xs" was declared but never referenced - uint16_t SC_Accumulation_xs; -..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(72): warning: #177-D: variable "SC_Accumulation_zs_reverse" was declared but never referenced - uint32_t SC_Accumulation_zs_reverse; -..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(73): warning: #177-D: variable "SC_Accumulation_xs_reverse" was declared but never referenced - uint16_t SC_Accumulation_xs_reverse; -..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(74): warning: #177-D: variable "WC_Accumulation_zs_reverse" was declared but never referenced - uint32_t WC_Accumulation_zs_reverse; -..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(75): warning: #177-D: variable "WC_Accumulation_xs_reverse" was declared but never referenced - uint16_t WC_Accumulation_xs_reverse; -..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(77): warning: #177-D: variable "WC_Accumulation_reverse" was declared but never referenced - double WC_Accumulation_reverse; -..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(78): warning: #177-D: variable "SC_Accumulation_reverse" was declared but never referenced - double SC_Accumulation_reverse; -..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c: 8 warnings, 0 errors -linking... -Program Size: Code=12588 RO-data=2528 RW-data=88 ZI-data=19152 -FromELF: creating hex file... After Build - User command #1: fromelf --bin -o ".\bin_file\SZV103_FM33A0_MainSystem.bin" "E:\GasFlowmeter\Internet_of_things_valve\SZV103\SZV103_FM33A0xxEV_SiZhu\KEIL_MDKARM\Objects\SZV103_FM33A0_MainSystem.axf" -".\Objects\SZV103_FM33A0_MainSystem.axf" - 0 Error(s), 8 Warning(s). +".\Objects\SZV103_FM33A0_MainSystem.axf" - 0 Error(s), 0 Warning(s). <h2>Software Packages used:</h2> -- Gitblit v1.9.3