From 6e3f1f560d618b37ee1a47fa2b0f682b70c3ef1c Mon Sep 17 00:00:00 2001
From: jinlicong <493886250@qq.com>
Date: Wed, 19 Jun 2024 17:25:45 +0800
Subject: [PATCH] 增加OTA协议

---
 KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm |   30 +++++-------------------------
 1 files changed, 5 insertions(+), 25 deletions(-)

diff --git a/KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm b/KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm
index e597efb..97805e7 100644
--- a/KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm
+++ b/KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm
@@ -22,34 +22,14 @@
  
 <h2>Project:</h2>
 E:\GasFlowmeter\Internet_of_things_valve\SZV103\SZV103_FM33A0xxEV_SiZhu\KEIL_MDKARM\SZV103_FM33A0_MainSystem.uvprojx
-Project File Date:  04/24/2024
+Project File Date:  06/13/2024
 
 <h2>Output:</h2>
 *** Using Compiler 'V5.06 update 7 for Certification (build 960)', folder: 'D:\Program Files\MDK5\ARM\ARMCC\Bin'
 Build target 'SZV103_FM33A0_MainSystem'
-compiling rs485_data_analysis_pro.c...
-..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(68): warning:  #177-D: variable "SC_Accumulation_zs"  was declared but never referenced
-  	uint32_t SC_Accumulation_zs;
-..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(69): warning:  #177-D: variable "SC_Accumulation_xs"  was declared but never referenced
-  	uint16_t SC_Accumulation_xs;
-..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(72): warning:  #177-D: variable "SC_Accumulation_zs_reverse"  was declared but never referenced
-  	uint32_t SC_Accumulation_zs_reverse;
-..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(73): warning:  #177-D: variable "SC_Accumulation_xs_reverse"  was declared but never referenced
-  	uint16_t SC_Accumulation_xs_reverse;
-..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(74): warning:  #177-D: variable "WC_Accumulation_zs_reverse"  was declared but never referenced
-  	uint32_t WC_Accumulation_zs_reverse;
-..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(75): warning:  #177-D: variable "WC_Accumulation_xs_reverse"  was declared but never referenced
-  	uint16_t  WC_Accumulation_xs_reverse;
-..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(77): warning:  #177-D: variable "WC_Accumulation_reverse"  was declared but never referenced
-  	double WC_Accumulation_reverse;
-..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(78): warning:  #177-D: variable "SC_Accumulation_reverse"  was declared but never referenced
-  	double SC_Accumulation_reverse;
-..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c: 8 warnings, 0 errors
-linking...
-Program Size: Code=12588 RO-data=2528 RW-data=88 ZI-data=19152  
-FromELF: creating hex file...
+Note: source file '..\Function\modbus\rtu\mbcrc.c' - object file renamed from '.\Objects\mbcrc.o' to '.\Objects\mbcrc_1.o'.
 After Build - User command #1: fromelf --bin -o ".\bin_file\SZV103_FM33A0_MainSystem.bin" "E:\GasFlowmeter\Internet_of_things_valve\SZV103\SZV103_FM33A0xxEV_SiZhu\KEIL_MDKARM\Objects\SZV103_FM33A0_MainSystem.axf"
-".\Objects\SZV103_FM33A0_MainSystem.axf" - 0 Error(s), 8 Warning(s).
+".\Objects\SZV103_FM33A0_MainSystem.axf" - 0 Error(s), 0 Warning(s).
 
 <h2>Software Packages used:</h2>
 
@@ -66,9 +46,9 @@
 <h2>Collection of Component Files used:</h2>
 
    * Component: Keil::Device:Startup:1.0.0
-      Source file:   Device/Source/system_FM33A0XXEV.c
       Source file:   Device/Source/ARM/startup_FM33A0XXEV.s
-Build Time Elapsed:  00:00:01
+      Source file:   Device/Source/system_FM33A0XXEV.c
+Build Time Elapsed:  00:00:02
 </pre>
 </body>
 </html>

--
Gitblit v1.9.3