forked from SZV10X_Software/SZV103_FM33A0xxEV_SiZhu

jinlicong
2024-05-15 d14dd3a2106de793fbe08dc5a12cf80defd3258a
KEIL_MDKARM/Objects/SZV103_FM33A0_MainSystem.build_log.htm
@@ -22,34 +22,24 @@
 
<h2>Project:</h2>
E:\GasFlowmeter\Internet_of_things_valve\SZV103\SZV103_FM33A0xxEV_SiZhu\KEIL_MDKARM\SZV103_FM33A0_MainSystem.uvprojx
Project File Date:  04/24/2024
Project File Date:  05/14/2024
<h2>Output:</h2>
*** Using Compiler 'V5.06 update 7 for Certification (build 960)', folder: 'D:\Program Files\MDK5\ARM\ARMCC\Bin'
Build target 'SZV103_FM33A0_MainSystem'
compiling rs485_data_analysis_pro.c...
..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(68): warning:  #177-D: variable "SC_Accumulation_zs"  was declared but never referenced
     uint32_t SC_Accumulation_zs;
..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(69): warning:  #177-D: variable "SC_Accumulation_xs"  was declared but never referenced
     uint16_t SC_Accumulation_xs;
..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(72): warning:  #177-D: variable "SC_Accumulation_zs_reverse"  was declared but never referenced
     uint32_t SC_Accumulation_zs_reverse;
..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(73): warning:  #177-D: variable "SC_Accumulation_xs_reverse"  was declared but never referenced
     uint16_t SC_Accumulation_xs_reverse;
..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(74): warning:  #177-D: variable "WC_Accumulation_zs_reverse"  was declared but never referenced
     uint32_t WC_Accumulation_zs_reverse;
..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(75): warning:  #177-D: variable "WC_Accumulation_xs_reverse"  was declared but never referenced
     uint16_t  WC_Accumulation_xs_reverse;
..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(77): warning:  #177-D: variable "WC_Accumulation_reverse"  was declared but never referenced
     double WC_Accumulation_reverse;
..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c(78): warning:  #177-D: variable "SC_Accumulation_reverse"  was declared but never referenced
     double SC_Accumulation_reverse;
..\Function\FLOW_METER_DATA_COLLECT\rs485_data_analysis_pro.c: 8 warnings, 0 errors
compiling pulse_and_alarm_line.c...
..\Function\FLOW_METER_DATA_COLLECT\pulse_and_alarm_line.c(253): warning:  #177-D: variable "low_pwr_line_cnt"  was declared but never referenced
     static   uint8_t low_pwr_line_cnt=0;
..\Function\FLOW_METER_DATA_COLLECT\pulse_and_alarm_line.c(254): warning:  #177-D: variable "under_pwr_line_cnt"  was declared but never referenced
     static   uint8_t under_pwr_line_cnt=0;
..\Function\FLOW_METER_DATA_COLLECT\pulse_and_alarm_line.c(255): warning:  #177-D: variable "close_valve_line_cnt"  was declared but never referenced
     static   uint8_t close_valve_line_cnt=0;
..\Function\FLOW_METER_DATA_COLLECT\pulse_and_alarm_line.c: 3 warnings, 0 errors
linking...
Program Size: Code=12588 RO-data=2528 RW-data=88 ZI-data=19152
Program Size: Code=27024 RO-data=2528 RW-data=604 ZI-data=23596
FromELF: creating hex file...
After Build - User command #1: fromelf --bin -o ".\bin_file\SZV103_FM33A0_MainSystem.bin" "E:\GasFlowmeter\Internet_of_things_valve\SZV103\SZV103_FM33A0xxEV_SiZhu\KEIL_MDKARM\Objects\SZV103_FM33A0_MainSystem.axf"
".\Objects\SZV103_FM33A0_MainSystem.axf" - 0 Error(s), 8 Warning(s).
".\Objects\SZV103_FM33A0_MainSystem.axf" - 0 Error(s), 3 Warning(s).
<h2>Software Packages used:</h2>
@@ -68,7 +58,7 @@
   * Component: Keil::Device:Startup:1.0.0
      Source file:   Device/Source/system_FM33A0XXEV.c
      Source file:   Device/Source/ARM/startup_FM33A0XXEV.s
Build Time Elapsed:  00:00:01
Build Time Elapsed:  00:00:00
</pre>
</body>
</html>