| | | <h2>Project:</h2> |
| | | E:\GasFlowmeter\Internet_of_things_valve\SZV103\SZV103_FM33A0xxEV_SiZhu\KEIL_MDKARM\SZV103_FM33A0_MainSystem.uvprojx |
| | | Project File Date: 04/26/2024 |
| | | Project File Date: 05/14/2024 |
| | | |
| | | <h2>Output:</h2> |
| | | *** Using Compiler 'V5.06 update 7 for Certification (build 960)', folder: 'D:\Program Files\MDK5\ARM\ARMCC\Bin' |
| | | Build target 'SZV103_FM33A0_MainSystem' |
| | | compiling valve_control.c... |
| | | ..\Function\VALVE\valve_control.c(85): error: #136: struct "<unnamed>" has no field "valve_state" |
| | | switch (save_valve_para_g.valve_state) |
| | | ..\Function\VALVE\valve_control.c(83): warning: #177-D: variable "valve_status" was declared but never referenced |
| | | VALVE_STATUS valve_status; |
| | | ..\Function\VALVE\valve_control.c: 1 warning, 1 error |
| | | compiling upper_com_data_pro.c... |
| | | ..\Function\UPPER_COMPUTER\upper_com_data_pro.c(11): warning: #177-D: variable "count_i" was declared but never referenced |
| | | uint16_t count_i; |
| | | ..\Function\UPPER_COMPUTER\upper_com_data_pro.c: 1 warning, 0 errors |
| | | compiling rs485_data_analysis_pro.c... |
| | | compiling upper_com.c... |
| | | compiling system_run_fun.c... |
| | | ..\Soft\system_run_fun.c(153): warning: #1-D: last line of file ends without a newline |
| | | |
| | | ..\Soft\system_run_fun.c: 1 warning, 0 errors |
| | | compiling rs485_read_data.c... |
| | | ..\Function\FLOW_METER_DATA_COLLECT\rs485_read_data.c(120): warning: #940-D: missing return statement at end of non-void function "rs485ComSendHandle" |
| | | } |
| | | ..\Function\FLOW_METER_DATA_COLLECT\rs485_read_data.c(205): warning: #1-D: last line of file ends without a newline |
| | | } |
| | | ..\Function\FLOW_METER_DATA_COLLECT\rs485_read_data.c: 2 warnings, 0 errors |
| | | compiling main.c... |
| | | compiling system_mem_para.c... |
| | | ..\Function\STORAGE\system_mem_para.c(157): warning: #550-D: variable "return_flag" was set but never used |
| | | ErrorStatus return_flag = PASS; |
| | | ..\Function\STORAGE\system_mem_para.c(177): warning: #550-D: variable "return_flag" was set but never used |
| | | ErrorStatus return_flag = PASS; |
| | | ..\Function\STORAGE\system_mem_para.c: 2 warnings, 0 errors |
| | | ".\Objects\SZV103_FM33A0_MainSystem.axf" - 1 Error(s), 7 Warning(s). |
| | | compiling pulse_and_alarm_line.c... |
| | | ..\Function\FLOW_METER_DATA_COLLECT\pulse_and_alarm_line.c(253): warning: #177-D: variable "low_pwr_line_cnt" was declared but never referenced |
| | | static uint8_t low_pwr_line_cnt=0; |
| | | ..\Function\FLOW_METER_DATA_COLLECT\pulse_and_alarm_line.c(254): warning: #177-D: variable "under_pwr_line_cnt" was declared but never referenced |
| | | static uint8_t under_pwr_line_cnt=0; |
| | | ..\Function\FLOW_METER_DATA_COLLECT\pulse_and_alarm_line.c(255): warning: #177-D: variable "close_valve_line_cnt" was declared but never referenced |
| | | static uint8_t close_valve_line_cnt=0; |
| | | ..\Function\FLOW_METER_DATA_COLLECT\pulse_and_alarm_line.c: 3 warnings, 0 errors |
| | | linking... |
| | | Program Size: Code=27024 RO-data=2528 RW-data=604 ZI-data=23596 |
| | | FromELF: creating hex file... |
| | | After Build - User command #1: fromelf --bin -o ".\bin_file\SZV103_FM33A0_MainSystem.bin" "E:\GasFlowmeter\Internet_of_things_valve\SZV103\SZV103_FM33A0xxEV_SiZhu\KEIL_MDKARM\Objects\SZV103_FM33A0_MainSystem.axf" |
| | | ".\Objects\SZV103_FM33A0_MainSystem.axf" - 0 Error(s), 3 Warning(s). |
| | | |
| | | <h2>Software Packages used:</h2> |
| | | |
| | |
| | | <h2>Collection of Component Files used:</h2> |
| | | |
| | | * Component: Keil::Device:Startup:1.0.0 |
| | | Source file: Device/Source/ARM/startup_FM33A0XXEV.s |
| | | Source file: Device/Source/system_FM33A0XXEV.c |
| | | Target not created. |
| | | Build Time Elapsed: 00:00:01 |
| | | Source file: Device/Source/ARM/startup_FM33A0XXEV.s |
| | | Build Time Elapsed: 00:00:00 |
| | | </pre> |
| | | </body> |
| | | </html> |